Specifications
Specification Details For ANTRACK
| Product Glance | |
| Model | ANTRACK |
| Version | V1 |
| Capacity | 4 units ANTMINER (Hydro) |
| Maximum load, kW | 24 |
| Detailed Characteristics | |
| Hardware configuration | |
| Size (length*width*height), mm (without package) | 1000*600*2100 |
| Size (length*width*height), mm (with package) | 2260*1130*780 |
| Net weight, kg (without package) | 207 |
| Gross weight, kg (with package) | 300 |
| Network connection mode | EJ45 Ethernet 10/100M |
| Power supply | |
| Power supply AC input voltage, Volt(1-1) | 380~415 |
| Power supply AC input frequency range, Hz | 50~60 |
| Power supply AC Input current, Amp(1-2) | 80 |
| Fan | |
| Rated power, W | 120 |
| Noise, dBA@1m | 68 |
| Size (Length*Height*Thickness), mm | 280*280*80 |
| Pump | |
| Rated power, W | 450 |
| Noise, dBA@1m | 55 |
| Size (Length*Height*Thickness), mm | 360*210*268 |
| Plate Heat Exchanger | |
| Maximum heat exchange power, kW | 30 |
| Size (Length*Width* Height), mm | 305*106*64 |
| Diameter of water pipe connector, mm | DN20 |
| Environment requirements | |
| Ambient temperature, °C(1-3) | 15~45 |
| Water flow, L/min | 32.0~40.0 |
| Water pressure, bar | ≤3.5 |
| Working fluid(1-4) | Antifreeze (10%) |
| Liquid PH | 7.8~8.5 |
| Storage temperature, °C | -20~70 |
| Operation humidity(non-condensing), RH | 10~90% |
NOTE:
(1-1) Caution: Wrong input voltage may probably cause miner damaged.
(1-2) Three-phase AC input.
(1-3) Please keep the ANTRACK V1's ambient temperature between 15 °C and 45 °C. Maintain at least 1 m of clearance in front of and behind the unit, and ensure adequate room ventilation to prevent exhaust-air recirculation. Under normal operation, the miner's inlet-water temperature will be about 5 °C above ambient. When operating with older models (e.g. S19 Hyd., T19 Hyd., S19 Pro Hyd., S19 Pro+ Hyd., T19 Pro Hyd., S19 XP Hyd.), ensure the ambient temperature does not exceed 35 °C.
(1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.
PS: An ANTRACK unit features four rack slots, each equipped with one network cable and one power cable tailored for Hydro-cooling miners. The unit also includes a water pump, eight fans, a heat exchanger and a plate heat exchanger.
For smooth operation of the ANTRACK system, please prepare the following additional items:
• A three‑phase, five‑core 380–415 V AC power cable (6AWG)
• An Ethernet cable
• 20 L of 10 % antifreeze
Specification Details For S19 XP+ Hyd.
| Product Glance | |
| Model | S19 XP+ Hyd. |
| Version | 10 |
| Crypto algorithm/coins | SHA256 | BTC/BCH/BSV |
| Typical hashrate, TH/s(1-1) | 293 |
| Power on wall @35°C(1-2), Watt(1-1) | 5,567 |
| Power efficiency on wall @35°C(1-2), J/TH(1-1) | 19 |
| Detailed Characteristics | |
| Power Supply | |
| Phase | 3 |
| Input voltage, Volt(2-1) | 380~415 |
| Input Frequency Range, Hz | 50~60 |
| Input max current, Amp | 12 |
| Hardware Configuration | |
| Networking connection mode | RJ45 Ethernet 10/100M |
| Server Size (Length*Width*Height, w/o package), mm | 339*173*207 |
| Server Size (Length*Width*Height, with package), mm | 570*316*430 |
| Net weight, kg(2-2) | 14.8 |
| Gross weight, kg | 16.7 |
| Environment Requirements | |
|
Inlet coolant temperature,°C |
20~50 |
|
Coolant flow, L/min |
8.0~10.0 |
|
Coolant pressure, bar |
≤3.5 |
|
Working coolant(2-2) |
Antifreeze/ Pure water/Deionized water |
|
Coolant pH value |
Antifreeze: 7.0~9.0 Prue water: 6.5~7.5 Deionized water:8.5~9.5 |
|
Diameter of coolant pipe connector, mm |
OD10 |
| Storage temperature,°C | -20~70 |
| Operation humidity(non-condensing) , RH | 10~90% |
NOTE:
(1-1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
(1-2) Inlet coolant temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) For detailed working coolant use and maintenance instructions, please refer to "ANTSPACE HK3 Hydro Cooling Container & Dry-Wet Tower Product Manual", Chapter 9, Article 3, Point 6, "Maintenance of Coolant"!
PS: Please note that the Hydro-cooling miners are shipped without power cables.