Miner Shop
ANTRACK & Bitcoin Miner S19 XP Hyd. Package
ANTRACK & Bitcoin Miner S19 XP Hyd. Package
Couldn't load pickup availability
Product Glance | |
Model | ANTRACK |
Version | V1 |
Capacity | 4 units ANTMINER (Hydro) |
Maximum load, kW | 24 |
Detailed Characteristics | |
Hardware configuration | |
Size (length*width*height), mm (without package) | 1000*600*2100 |
Size (length*width*height), mm (with package) | 2260*1130*780 |
Net weight, kg (without package) | 207 |
Gross weight, kg (with package) | 300 |
Network connection mode | RJ45 Ethernet 10/100M |
Power supply | |
Power supply AC input voltage, Volt(1-1) | 380~415 AC |
Power supply AC input frequency range, Hz | 50~60 |
Power supply AC Input current, Amp(1-2) | 80 |
Fan | |
Rated power, W | 120 |
Noise, dBA@1m | 68 |
Size (Length*Height*Thickness), mm | 280*280*80 |
Pump | |
Rated power, W | 450 |
Noise, dBA@1m | 55 |
Size (Length*Height*Thickness), mm | 360*210*268 |
Plate Heat Exchanger | |
Maximum heat exchange power, kW | 30 |
Size (Length*Width* Height), mm | 305*106*64 |
Diameter of water pipe connector, mm | DN20 |
Environment requirements | |
Ambient temperature, °C(1-3) | 15~45 |
Water flow, L/min | 32.0~40.0 |
Water pressure, bar | ≤3.5 |
Working fluid(1-4) | Antifreeze (10%) |
Liquid PH | 7.8~8.5 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
NOTE:
(1-1) Caution: Wrong input voltage may probably cause miner damaged.
(1-2) Three-phase AC input.
(1-3) Please keep the ANTRACK V1's ambient temperature between 15 °C and 45 °C. Maintain at least 1 m of clearance in front of and behind the unit, and ensure adequate room ventilation to prevent exhaust-air recirculation. Under normal operation, the miner's inlet-water temperature will be about 5 °C above ambient. When operating with older models (e.g. S19 Hyd., T19 Hyd., S19 Pro Hyd., S19 Pro+ Hyd., T19 Pro Hyd., S19 XP Hyd.), ensure the ambient temperature does not exceed 35 °C.
(1-4) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.
PS: An ANTRACK unit features four rack slots, each equipped with one network cable and one power cable tailored for Hydro-cooling miners. The unit also includes a water pump, eight fans, a heat exchanger and a plate heat exchanger.
For smooth operation of the ANTRACK system, please prepare the following additional items:
• A three‑phase, five‑core 380–415 V AC power cable (6AWG)
• An Ethernet cable
• 20 L of 10 % antifreeze
Share