Miner Shop
ANTRACK & Bitcoin Miner T19 Hyd. Package
ANTRACK & Bitcoin Miner T19 Hyd. Package
Couldn't load pickup availability
Specification Details For ANTRACK
Product Glance | |
Model | ANTRACK |
Version | V1 |
Capacity | 4 units ANTMINER (Hydro) |
Maximum load, kW | 24 |
Detailed Characteristics | |
Hardware configuration | |
Size (length*width*height), mm (without package) | 1000*600*2100 |
Size (length*width*height), mm (with package) | 2260*1130*780 |
Net weight, kg (without package) | 207 |
Gross weight, kg (with package) | 300 |
Network connection mode | EJ45 Ethernet 10/100M |
Power supply | |
Power supply AC input voltage, Volt(1-1) | 380~415 |
Power supply AC input frequency range, Hz | 50~60 |
Power supply AC Input current, Amp(1-2) | 80 |
Fan | |
Rated power, W | 120 |
Noise, dBA@1m | 68 |
Size (Length*Height*Thickness), mm | 280*280*80 |
Pump | |
Rated power, W | 450 |
Noise, dBA@1m | 55 |
Size (Length*Height*Thickness), mm | 360*210*268 |
Plate Heat Exchanger | |
Maximum heat exchange power, kW | 30 |
Size (Length*Width* Height), mm | 305*106*64 |
Diameter of water pipe connector, mm | DN25 |
Environment requirements | |
Ambient temperature, °C | 15~45 |
Water flow, L/min | 32.0~40.0 |
Water pressure, bar | ≤3.5 |
Working fluid(1-3) | Antifreeze (10%) |
Liquid PH | 7.8~8.5 |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing), RH | 10~90% |
NOTE:
(1-1) Caution: Wrong input voltage may probably cause miner damaged.
(1-2) Three-phase AC input.
(1-3) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.
Specification Details For T19 Hyd.
Product Glance | |
Model | T19 Hyd. |
Version | 208-A |
Algorithm | Cryptocurrency | SHA256 | BTC/BCH/BSV |
Typical Hashrate, TH/s(1-1) | 138.5 |
Power on wall @35°C(1-2), Watt(1-1) | 5194 |
Power efficiency on wall @35°C(1-2), J/TH(1-1) | 37.5 |
Detailed Characteristics | |
Power Supply | |
Power supply AC Input voltage, Volt(2-1) | 342~418 AC |
Power supply AC Input Frequency Range, Hz | 47~63 |
Power supply AC Input current, Amp(2-2) | 30 |
Hardware Configuration | |
Networking connection mode | RJ45 Ethernet 10/100M |
Miner Size (Length*Width*Height, w/o package), mm | 410*196*209 |
Miner Size (Length*Width*Height, with package), mm | 570*316*430 |
Net weight, kg | 15.2 |
Gross weight, kg | 17.5 |
Environment Requirements | |
Inlet water temperature, °C | 35 |
Water flow, L/min | 8.0~10.0 |
Water pressure, bar | ≤3.5 |
Working fluid(2-3) | Deionized water/Pure water/Antifreeze |
Storage temperature, °C | -20~70 |
Operation humidity(non-condensing) , RH | 10~90% |
NOTE:
(1-1) The Hashrate value, Power on wall, and Power efficiency on wall are all typical values. The actual Hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%.
(1-2) Inlet water temperature.
(2-1) Caution: Wrong input voltage may cause server damaged.
(2-2) Three-phase AC input, 10 A per wire.
(2-3) If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.